DCF77-Lightning protection

hopf Elektronik GmbH


Lightning protection FG444100

The lightning protection FG444000 has been replaced by the lightning protection FG444100.

Using outdoor antennas means that thunderstorms may cause very high interference voltages on the antenna cable. This can damage or even destroy not only the directly connected radio controlled clock system but also any other connected devices.lightning protection

Overvoltage as direct consequence from lightning cannot be avoided, but the device can be protected from destructive effects. It is therefore necessary to "short-circuit" all the lines with overvoltage and to reduce the overvoltage as quickly as possible. Afterwards the device should return to its original specifications.

The lightning protection is therefore a combination of different components. Fast absorber diodes with a response time of < 1 nsec and a discharge current of 5 kA keep the potential differences between antenna core and zero to a constant 12 V. The following gas arresters, when lit, short-circuit the lines to the earth connection point.


Technical Data

  • aluminium housing: 250 x 105 x 95 mm
  • input / output: BNC-connector female / female
  • earth connection point: screw M 6
  • weight: ca. 3.5 kg
  • response time: < 1 nsec
  • current stability 8/20 µsec wave: 5 kA
  • protection level at 6 kV 1.5/50 µsec, wave at input: < 12 V
  • input impedance: 50 Ohm
  • insertion loss: max. 3 dB

 

Installation

 


Further information you can find in the manual system information DCF77

 


homepage

+++ selection+++

top

© by hopf Elektronik GmbH  -  Nottebohmstr. 41  -   D-58511 Lüdenscheid  -  E-Mail: support@hopf.com